SPECIFICATIONS FOR ACC-U-SOUND PANELS


PART 1 GENERAL

1.1 Work in this section shall be subject to drawings, general conditions, schedules, addenda and other contract documents.

1.2 Submit______ samples of each type of acoustical panel as shown on the drawings and in schedules and include appropriate technical information including test data and maintenance instructions.

1.3 Acoustical panels shall be installed to manufacturers recommendations.

1.4 Installation of acoustical panels shall not begin until all wet work is completed and dry. Building shall be climatized and under standard occupancy conditions (temperature of 65 . 80 degrees and not more than 70% relative humidity) before installation begins.

1.5 Substitutions or changes will only be permitted by prior approval by the architect.


PART 2 MATERIALS

2.1 Acoustical wall panels shall be Quiet Technology Systems Type: ______(Choose Type) manufactured by Quiet Technology Systems, 255 N. Pasadena Street, Gilbert, AZ 85233. Phone (480) 632-9234 Fax (480) 632-9238.

2.2 Acoustical panels shall be constructed of single core construction of dimensionally stable medium density rigid 6 .7 lb. Pcf fiberglass.

2.3 Sizes:_______wide and_______high or as shown on drawings. Standard maximum size is 48" wide by 120" high nominal. Custom shapes or larger sizes available, consult manufacturer. Panels are to be manufactured according to field dimensions supplied by the installing contractor. Standard tolerances are plus or minus 1/16" in width and lengh.

2.4 Edge profile shall be: Square, radius, bevel, miter (choose one). Corner detail shall be: Square, radius, or custom (choose one). Edge treatment shall be resin hardened or aluminum (square only).

2.5 Panel finish shall be:__________________________(specify fabric manufacturer, pattern and color). Finish shall be applied directly to the face and edges of the panel and returned to the back of the panel 2" to provide a full finished edge. All corners are fully tailored.

2.6 Mounting shall be adhesive with impaling clip, z-clip, or spline (choose one). Adhesive, fasteners (ie: screws nails) and level clips to be supplied by the contractor. All other standard mounting brackets supplied by the manufacturer.

2.7 Acoustical performance . panels shall have a minimum NRC of_______ (specify) in accordance with ASTM C423

2.8 Flammability . All panels with standard fabric shall have a Class "A" flame spread rating of 25 or less in accordance with ASTM E-84.


ACC-U-SOUND ACOUSTICAL PANELS


QTS stocks a vast selection of ACC-U-SOUND panels to fit low, mid, or high frequency sound absorption challenges - all in a wide range of decorative and architectural treatments.

Our selection of panel coverings has been rigorously tested for safety and sound suppression. Products can be applied to a wide variety of applications including Schools to Private Home Studios.


Quiet Technology Systems